1dl code on goodman furnace - CODE: b9. RESULT: Indoor blower motor problem./Blocked filters./Restrictive/ undersized ductwork./Indoor-outdoor unit miss match. CODE: d0. RESULT: Air conditioner/heat pump is wired as part of a communicating system and integrated control module does not contain any shared data. CODE: d1.

 
Get professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long.. 4 plex

I have a Amana AM9C960603ANAA. I'm getting 2 codes on the LCD display. First is 1dl and the second one is EE5. What do - Answered by a verified HVAC TechnicianAbout Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... My brand new 2 ton Goodman is tripping the cb when outside 8/7/2023. I have an issue with my Goodman air conditioner, I do not 8/6/2023. I have a Goodman central air unit washed the condenser clean 8/6/2023. Ok. Opening a new thread I have got a Goodman heat pump unit 8/3/2023. I'm working on a Goodman 5 ton and the high pressure lines 8/1/2023.GOODMAN GAS FURNACE IO MANUAL GMS8 GDS8 GHS8 [PDF] (2005) Gas-Fired Warm Air Furnace, Single Stage, Category 1, Goodman Manufacturing Co., L.P. GOODMAN MES9 & CES9 FURNACE INSTALLATION INSTRUCTIONS [PDF] (2019) GOODMAN FURNACE HIGH TEMPERATURE PLASTIC VENT HTPV SAFETY RECALL [Web article] US CPSC notice No Still going up this codes. F01 EE0. HVAC Technician: airheatman. If it lights and goes out try cleaning the flame sensor and see if that helps. Code says the board is not receiving signal that we are getting flame. Ask Your Own HVAC Question. HVAC Technician: airheatman.GMVC95 goodman furnace issue I had a brand new GMVC951155DXA installed in my house, along with a Comfortnet CTK03 thermostat, and brand new DSZC16 heat pump. Immediately after starting the system, I had a prompt on the thermostat that says E2 PS1 (Low pressure switch stuck open).GMVC95 goodman furnace issue I had a brand new GMVC951155DXA installed in my house, along with a Comfortnet CTK03 thermostat, and brand new DSZC16 heat pump. Immediately after starting the system, I had a prompt on the thermostat that says E2 PS1 (Low pressure switch stuck open).ERROR LIGHT = Y. SUGGESTED ACTION = Clean Condenser Coils, Check Fan for fault. Code will reset afier cleaning. CODE = C5. AIRF LOW ALERT. STATUS = Outdoor Coil temperature too high for outdoor ambient temperature. DISPLAY = N. ERROR LIGHT = Y. SUGGESTED ACTION = Check for Blocked Outdoor Air or Clean Coil. Most popular furnace brands in Canada There are several popular furnace brands available in Canada, and the most popular ones are: Lennox Carrier Trane Bryant York Goodman Rheem American Standard Armstrong Air Napoleon These brands offer a range of furnace... My goodman furnace's diagnostic display reads 88. I was away for work and my girlfriend said it was reading e5 so I got her to cut power and change 3 amp fuse. Now it says 88 and im stumped. Furnace d … read moreJan 24, 2023 · goodman furnace tech support. Its a 2018 model goodman and i get 3 led flashes, the igniter glows real bright and then dims. We tried to jump the pressure switch but the furnace did the same thing it … read more The flashing LEDs on your furnace will correspond to a specific fault code that is shown here on their diagnostic chart.Goodman is one of the biggest names i...67. Ambient Temperature Sensor Fault (Out of Range – Open or Shorted) ERR 67. 6 Flash. Coil Temperature Sensor Fault (Out of Range – Open or Shorted) Low Pressure Cut Out Fault (Open outside of defrost Cycle-Hard lock out, cycle power to reset) ERR 79.Jan 4, 2023 · Get professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long. code (if there is no fault or protection code it will be display “nn”) Normal display Display “--” Operating mode 3—Heating; 4—Forced cooling) Operating fan speed grade (0—Power off) The total capacity requirements of the interior unit The capacity requirements of the revised external unit T3 piping temperature T4 environmert ...The Goodman furnace error code 1dl is a common error code associated with Goodman furnaces that indicates a problem with the hot surface ignitor. When this error code appears, it usually indicates that the hot surface ignitor has failed and needs to be replaced. This article will provide an overview of this error code and discuss how to ... specified on the furnace rating plate and OPERATIONAL CHECKS section of these instructions. When furnace duct(s) supply air outside the space contain-ing the furnace, a return air duct must terminate in the same space as the supply duct and be sealed to the furnace casing. A gas-fired furnace for installation in a residential garage Jan 12, 2023 · Get professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long. The AVPTC61D14 air handler is rated for an output of 5 tons. In many cases, this tonnage will be larger than the condenser it is paired with, which increases the overall efficiency of the unit. Please note that this air handler needs a condenser to heat or cool. For straight heating or when backup heat is necessary in a heat pump application ...Besides Goodman fault codes, there are the messages which can also appear, status and data related to these codes. This information can give you the idea about any necessary further actions – for example, 3 flashes mean that Goodman pressure switch stuck open, and 2 flashes mean the same part stuck closed.FIX: Adjust the gas pressure according to the information available to you. CODE: Eight LED flashes. PROBLEM: This means your furnace has an igniter circuit problem due to a defective igniter or an improperly connected igniter. FIX: Replace the igniter or check the ground wiring for defects. CODE: Nine LED flashes.Jan 25, 2020 · 1. the thermostat demand signal is intermittent. 2. Time delay relay or control board faulty. 3. If high pressure switch is present, go to Flash Code 2 information. 4. If a low pressure switch is present, go to Flash Code 1 information. Status LED: Yellow “ALERT” Flash Code 4. Status LED Description: off rotor. Purchase Your HVAC Equipment Direct | Goodman AC And Furnace ... We experienced a power outage and when the power came back on our furnace blows cold air but will not ignite. I believe it is a 3 yr. old Goodman model no. CAPF486OC6AA. I noticed a blinking code of 4 … read moreHow to Replace Your Air Filter. Open the access door on your Goodman furnace by pulling it towards you, revealing the filter inside. Carefully remove the filter by hand. Vacuum any dust or debris that may have accumulated on the filter housing of the furnace. Slide in the replacement filter. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...Jan 4, 2023 · Get professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long. https://www.alwaysopen.caGoodman Furnace Fault CodesJan 18, 2014 · GMVC95 goodman furnace issue I had a brand new GMVC951155DXA installed in my house, along with a Comfortnet CTK03 thermostat, and brand new DSZC16 heat pump. Immediately after starting the system, I had a prompt on the thermostat that says E2 PS1 (Low pressure switch stuck open). As an armature, I have some experience troubleshooting furnace problems. I have a 1.5 ton Goodman furnace that cools and heats. The circuit bd. Is B25578-00A. The unit is 25 years old and has been wor … read moreSelect the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.I am always available if you want to use your “Request Call Option “ And if you don’t get another message right after this greeting it’s because I’m more then likely I’m in the process of writing another message to you. that number is ***** the air conditioning coil that is on top of the furnace.View and Download Goodman AVPTC42D14 series installation & operating instructions manual online. AVPTC**14 series. AVPTC42D14 series air handlers pdf manual download. Also for: Avptc48d14 series, Avptc30c14 series, Avptc36c14 series, Avptc24b14 series, Avptc48c14 series, Avptc60d14... No Still going up this codes. F01 EE0. HVAC Technician: airheatman. If it lights and goes out try cleaning the flame sensor and see if that helps. Code says the board is not receiving signal that we are getting flame. Ask Your Own HVAC Question. HVAC Technician: airheatman.GMVC95 goodman furnace issue I had a brand new GMVC951155DXA installed in my house, along with a Comfortnet CTK03 thermostat, and brand new DSZC16 heat pump. Immediately after starting the system, I had a prompt on the thermostat that says E2 PS1 (Low pressure switch stuck open).We experienced a power outage and when the power came back on our furnace blows cold air but will not ignite. I believe it is a 3 yr. old Goodman model no. CAPF486OC6AA. I noticed a blinking code of 4 … read more4th of July Deals - Purchase Your HVAC Equipment Direct ...My brand new 2 ton Goodman is tripping the cb when outside 8/7/2023. I have an issue with my Goodman air conditioner, I do not 8/6/2023. I have a Goodman central air unit washed the condenser clean 8/6/2023. Ok. Opening a new thread I have got a Goodman heat pump unit 8/3/2023. I'm working on a Goodman 5 ton and the high pressure lines 8/1/2023.Besides Goodman fault codes, there are the messages which can also appear, status and data related to these codes. This information can give you the idea about any necessary further actions – for example, 3 flashes mean that Goodman pressure switch stuck open, and 2 flashes mean the same part stuck closed.GOODMAN GAS FURNACE IO MANUAL GMS8 GDS8 GHS8 [PDF] (2005) Gas-Fired Warm Air Furnace, Single Stage, Category 1, Goodman Manufacturing Co., L.P. GOODMAN MES9 & CES9 FURNACE INSTALLATION INSTRUCTIONS [PDF] (2019) GOODMAN FURNACE HIGH TEMPERATURE PLASTIC VENT HTPV SAFETY RECALL [Web article] US CPSC notice Welcome to TWINTECH Heating & Cooling Keeping families comfortable for over 30 years. Check out our seasonal promotions. TWINTECH is a full-service HVAC care and maintenance provider located in Durham, Ontario.I have problem with bryant furnace mod#379CAV036070AGJA just to call for heat the board display code #12 (HK42FZ011) so we wait some time and after that the board run a perfect cycle,run inducer,fire …The AVPTC61D14 air handler is rated for an output of 5 tons. In many cases, this tonnage will be larger than the condenser it is paired with, which increases the overall efficiency of the unit. Please note that this air handler needs a condenser to heat or cool. For straight heating or when backup heat is necessary in a heat pump application ... Goodman furnaces are among the most recognized and respected forced-air heating systems. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Many components ...FIX: Check your Goodman furnace for a pinched or blocked pressure switch hose. CODE: Continuous LED flashes PROBLEM: This means that your furnace has a reversed polarity of 115 volts. FIX: You will have to correct the wiring polarity after reviewing the wiring diagram. goodman furnace codes GOODMAN GAS FURNACE IO MANUAL GMS8 GDS8 GHS8 [PDF] (2005) Gas-Fired Warm Air Furnace, Single Stage, Category 1, Goodman Manufacturing Co., L.P. GOODMAN MES9 & CES9 FURNACE INSTALLATION INSTRUCTIONS [PDF] (2019) GOODMAN FURNACE HIGH TEMPERATURE PLASTIC VENT HTPV SAFETY RECALL [Web article] US CPSC notice Goodman Furnace Fault Codes. Goodman furnaces come highly recommended by furnace specialists in Edmonton. The brand is well-built and reliable. But, as with any furnace, Goodman units can experience issues - especially since cold Alberta winters can take such a toll on these types of appliances.Once again Twin Tech came through and fixed my furnace. A young man by the name of Mitch came by tonight and he was so nice explained everything he was quick he was clean he turned off the lights even when he left the furnace room it s just above and beyond Twin Tech always delivers and I just found out about them last year and I will use no one else but thanks again Mitch you are fantasticMar 1, 2022 · Code 1 – Furnace ignition failure. The control board has detected that the furnace failed to ignite. The control board has detected that the furnace failed to ignite. This could be due to low voltage, high resistance, or dirty terminals on the furnace primary control. Nov 30, 2019 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... ItsAShitParty • 1 yr. ago. 1DL means idle as in no the system is not getting any signals from the thermostat. F04 means fan CFM. The 04 would indicate 400 cfm. This is a continuous usually fan CFM. Your system is not getting any heating or cooling signal/running the fan at low speed.Troubleshooting b1 fault code on a Goodman communicating air handler HVAC Technician: airheatman , HVAC Technician replied 7 years ago Take a look at this manual on troubleshooting these motors and let me know if you want to get the tester and determine if issue is in motor or boardSelect the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button. Feb 10, 2023 · Besides Goodman fault codes, there are the messages which can also appear, status and data related to these codes. This information can give you the idea about any necessary further actions – for example, 3 flashes mean that Goodman pressure switch stuck open, and 2 flashes mean the same part stuck closed. Welcome to TWINTECH Heating & Cooling Keeping families comfortable for over 30 years. Check out our seasonal promotions. TWINTECH is a full-service HVAC care and maintenance provider located in Durham, Ontario.1. the thermostat demand signal is intermittent. 2. Time delay relay or control board faulty. 3. If high pressure switch is present, go to Flash Code 2 information. 4. If a low pressure switch is present, go to Flash Code 1 information. Status LED: Yellow “ALERT” Flash Code 4. Status LED Description: off rotor.AMANA & GOODMAN FAULT CODES. 1. One led flash that stays on continuously = No signal from thermostat. Turn off power and check connections. 2. One led that flashes = Furnace lockout after three attempts to fire. Must be reset by lowering it for twenty seconds and then raise it back. After one hour furnace will reset itself. 3.ERROR LIGHT = Y. SUGGESTED ACTION = Clean Condenser Coils, Check Fan for fault. Code will reset afier cleaning. CODE = C5. AIRF LOW ALERT. STATUS = Outdoor Coil temperature too high for outdoor ambient temperature. DISPLAY = N. ERROR LIGHT = Y. SUGGESTED ACTION = Check for Blocked Outdoor Air or Clean Coil. Jan 4, 2023 · Get professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long. The controller will indicate a fault condition by flashing the fault LED. The flashing pattern will be ¼ second on and ¼ second off for each count, if multiple faults are present it will dwell 2 seconds between each fault code, then dwell 5 seconds and repeat until the fault(s) are cleared. Listed below are the fault codes. 1 flash – Not Used Goodman furnaces are among the most recognized and respected forced-air heating systems. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Many components ...The AVPTC61D14 air handler is rated for an output of 5 tons. In many cases, this tonnage will be larger than the condenser it is paired with, which increases the overall efficiency of the unit. Please note that this air handler needs a condenser to heat or cool. For straight heating or when backup heat is necessary in a heat pump application ... I am always available if you want to use your “Request Call Option “ And if you don’t get another message right after this greeting it’s because I’m more then likely I’m in the process of writing another message to you. that number is ***** the air conditioning coil that is on top of the furnace.The furnace filter is generally on the return duct right before the furnace. A dirty filter causes blockage of airflow. A dirty filter causes blockage of airflow. This results in a furnace overheating and shuts off too quickly before your house gets heated up.Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button. FIX: Check your Goodman furnace for a pinched or blocked pressure switch hose. CODE: Continuous LED flashes PROBLEM: This means that your furnace has a reversed polarity of 115 volts. FIX: You will have to correct the wiring polarity after reviewing the wiring diagram. goodman furnace codes Dec 19, 2022 · Goodman furnace isn’t blowing hot air. First, check your thermostat if your Goodman furnace isn’t blowing hot air. It should be set to “auto” and “heat.”. If it’s set to “on,” your fan will blow air constantly, even when it’s not actively heating. Next, check your air filter. You should change your furnace air filter regularly. Dec 21, 2011 · AMANA & GOODMAN FAULT CODES. 1. One led flash that stays on continuously = No signal from thermostat. Turn off power and check connections. 2. One led that flashes = Furnace lockout after three attempts to fire. Must be reset by lowering it for twenty seconds and then raise it back. After one hour furnace will reset itself. 3. The controller will indicate a fault condition by flashing the fault LED. The flashing pattern will be ¼ second on and ¼ second off for each count, if multiple faults are present it will dwell 2 seconds between each fault code, then dwell 5 seconds and repeat until the fault(s) are cleared. Listed below are the fault codes. 1 flash – Not Used Dec 19, 2022 · Goodman furnace isn’t blowing hot air. First, check your thermostat if your Goodman furnace isn’t blowing hot air. It should be set to “auto” and “heat.”. If it’s set to “on,” your fan will blow air constantly, even when it’s not actively heating. Next, check your air filter. You should change your furnace air filter regularly. Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.GMVC95 goodman furnace issue I had a brand new GMVC951155DXA installed in my house, along with a Comfortnet CTK03 thermostat, and brand new DSZC16 heat pump. Immediately after starting the system, I had a prompt on the thermostat that says E2 PS1 (Low pressure switch stuck open).FIX: Adjust the gas pressure according to the information available to you. CODE: Eight LED flashes. PROBLEM: This means your furnace has an igniter circuit problem due to a defective igniter or an improperly connected igniter. FIX: Replace the igniter or check the ground wiring for defects. CODE: Nine LED flashes.We experienced a power outage and when the power came back on our furnace blows cold air but will not ignite. I believe it is a 3 yr. old Goodman model no. CAPF486OC6AA. I noticed a blinking code of 4 … read more No signal from the thermostat. Turn off the unit’s power and check connections. Single LIGHT flash. Furnace lockout due to an excessive number of ignition retries. Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour. 2 LIGHT flashes.Mar 26, 2022 · I am always available if you want to use your “Request Call Option “ And if you don’t get another message right after this greeting it’s because I’m more then likely I’m in the process of writing another message to you. that number is ***** the air conditioning coil that is on top of the furnace. Feb 10, 2023 · 67. Ambient Temperature Sensor Fault (Out of Range – Open or Shorted) ERR 67. 6 Flash. Coil Temperature Sensor Fault (Out of Range – Open or Shorted) Low Pressure Cut Out Fault (Open outside of defrost Cycle-Hard lock out, cycle power to reset) ERR 79. October 28, 2021 Goodman furnaces have a display panel with a built-in trouble-code that uses LED lights to show the homeowner that there is a malfunction of some sort. What do these error codes mean and is there anything that you can do to fix these problems? Here is everything that you need to know. Goodman Furnace Error CodesMay 11, 2019 · STATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return. Dec 17, 2015 · I need your assistance with the Amana and Goodman furnace E5 error code.After the LED segment 2 shows you E and the segment one shows the 5, this is one of t... Apr 12, 2023 · No signal from the thermostat. Turn off the unit’s power and check connections. Single LIGHT flash. Furnace lockout due to an excessive number of ignition retries. Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour. 2 LIGHT flashes. Turn off the furnace or the breaker box. Check the filter to make sure it’s clean, and replace it if necessary. Inspect the furnace and vents for dirt and debris, and vacuum them if necessary. Turn the furnace back on. Check that the thermostat is set to Heat and set for higher than room temperature.To receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year or 2-Year Unit Replacement Limited Warranty, 20-Year Heat Exchanger Limited Warranty, and 10-Year Parts Limited Warranty, online registration must be completed ... CODE: 2 Flashes. RESULT: The furnace is likely blowing cold air because it's dropping the flame. CODE: 3 Flashes. RESULT: Indicates a problem with the pressure switch. CODE: 4 Flashes. RESULT: Indicates a problem with the limit switch. CODE: 6 Flashes. RESULT: Indicates a problem with the polarity or grounding.Jul 27, 2022 · I have problem with bryant furnace mod#379CAV036070AGJA just to call for heat the board display code #12 (HK42FZ011) so we wait some time and after that the board run a perfect cycle,run inducer,fire …

How to Replace Your Air Filter. Open the access door on your Goodman furnace by pulling it towards you, revealing the filter inside. Carefully remove the filter by hand. Vacuum any dust or debris that may have accumulated on the filter housing of the furnace. Slide in the replacement filter.. Pinochle free

1dl code on goodman furnace

Turn off the furnace power and repair a short or replace the pressure switch. 4. Read three LED flashes to mean your furnace has an open pressure switch circuit or it has an induced draft blower operating. Check the pressure switch hose of your furnace for blocks or an improper connection.My brand new 2 ton Goodman is tripping the cb when outside 8/7/2023. I have an issue with my Goodman air conditioner, I do not 8/6/2023. I have a Goodman central air unit washed the condenser clean 8/6/2023. Ok. Opening a new thread I have got a Goodman heat pump unit 8/3/2023. I'm working on a Goodman 5 ton and the high pressure lines 8/1/2023.The furnace filter is generally on the return duct right before the furnace. A dirty filter causes blockage of airflow. A dirty filter causes blockage of airflow. This results in a furnace overheating and shuts off too quickly before your house gets heated up. specified on the furnace rating plate and OPERATIONAL CHECKS section of these instructions. When furnace duct(s) supply air outside the space contain-ing the furnace, a return air duct must terminate in the same space as the supply duct and be sealed to the furnace casing. A gas-fired furnace for installation in a residential garage Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.Having a trane furnace with the code 1DL can be an indication of a problem. Understanding this code and addressing the underlying problem is key to ensuring that your furnace operates as intended. This article will discuss the trane furnace code 1DL, its potential causes, and how you can address them. — The Trane furnace code 1DL is a ... The rollout switches detect heat where it shouldn’t be. Faulty switches are indicated by nine flashes on the Goodman furnace LED. You can try replacing your furnace filter or contact technicians if it does not work. Call Immediate Services To Fix Your Furnace Issues Today. You may be able to fix most of your furnace issues by following the ... FIX: Check your Goodman furnace for a pinched or blocked pressure switch hose. CODE: Continuous LED flashes PROBLEM: This means that your furnace has a reversed polarity of 115 volts. FIX: You will have to correct the wiring polarity after reviewing the wiring diagram. goodman furnace codesFIX: Check your Goodman furnace for a pinched or blocked pressure switch hose. CODE: Continuous LED flashes PROBLEM: This means that your furnace has a reversed polarity of 115 volts. FIX: You will have to correct the wiring polarity after reviewing the wiring diagram. goodman furnace codes Having a trane furnace with the code 1DL can be an indication of a problem. Understanding this code and addressing the underlying problem is key to ensuring that your furnace operates as intended. This article will discuss the trane furnace code 1DL, its potential causes, and how you can address them. — The Trane furnace code 1DL is a ... Some simple Diy troubleshooting a Goodman furnace with no flame and the computer board putting out a number 1 flash code.Amazon link to Great products that e...ItsAShitParty • 1 yr. ago. 1DL means idle as in no the system is not getting any signals from the thermostat. F04 means fan CFM. The 04 would indicate 400 cfm. This is a continuous usually fan CFM. Your system is not getting any heating or cooling signal/running the fan at low speed..